Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Model No.: SRT-CT1HA1E
Brand: Sendo or OEM
Place Of Origin: China
Status: New
Service System: Free Spare Parts, Field Maintenance And Repair Service, Onsite Installation
Warranty Service: 1 Year
Species: Central Air Conditioners
Certification: Ce
Heating And Cooling Function: Cooling/Heating
Kind Of Power: Electric
Fixed Frequency / Variable Frequency: Variable Frequency
Packaging: Plastic Film or Plywood Case
Transportation: Ocean
Place of Origin: China
Certificate: ISO9001, ISO14001, CE
HS Code: 8418
Port: Tianjin
Payment Type: L/C,T/T
Incoterm: FOB,CFR,CIF,EXW
Rooftop Packaged Unit R410A with Copeland Scroll Compressors (Inverter) and Ec Plug Fan
Key benefits of Rooftop Packaged Unit R410A with Copeland Scroll Compressors (Inverter) and Ec Plug Fan include: (High efficiency EC fan technology) Program control feature for exact airflow requirements; High static easily achieved; Eliminates belt dust and belt adjustment, providing a cleaner environment, and lowers operational maintenance cost; Significant time saved for on-site commissioning; Improved occupant comfort. EC plug fans deliver exact airflow requirements while minimising power usage at the same time. In fact EC plug fan technology is up to 50% more efficient than traditional belt and pulley systems. This provides enhanced comfort and improved maintenance of system performance.
Key benefits of optional high efficiency DC Inverter compressor include: Rapid warm up and cool down, the DC Inverter Compressor system reaches full load rapidly providing less temperature fluctuation and an improved living environment.
Features
CASING/STRUCTURE
The casing is made of zinc coated galvanised steel sheets. It is further treated with an electrostatic powder coat then over baked to provide a weather resistant finish to suit the harsh climate. The screws are also zinc plated to improved product durability.
COMPRESSOR
High efficiency scroll type compressor is hermetically sealed, quiet running and supported on rubber mounts to minimise vibration. All compressors are provided with an internal overload protection, and incorporate crankcase heater for smooth start-up under any conditions. High efficiency DC Inverter compressors is optional.
CONDENSER AND EVAPORATOR
The condenser and evaporator coils are manufactured from seamless copper tubes mechanically bonded to blue hydrophilic aluminium fins to ensure optimum heat transfer. The shoulder of each fin adjoins the shoulder of the adjacent fin, completely encasing the copper tubes for maximum heat transfer. The generously sized coils provide ample capacity under all normal operating conditions. All coils are pressure tested to 450Psi at the factory to avoid leakage. To improve corrosion resistance, a hydrophilic Gold Fin is provided as optional.
CONDENSER FAN AND MOTOR
Direct driven propeller axial fans are used for maximum condensing efficiency.
EVAPORATOR FAN AND MOTOR
EC is fitted with a plug-fan ensuring that no belt particles can be carried away into the building, this ventilation system is compliant with EN13779 air quality norm. EC plug fans deliver exact airflow requirements while minimising power usage, and are up to 50% more efficient versus traditional belt and pulley systems.
INSULATION
Ripple type acoustic insulation for compressor section, low noise. To prevent the likelihood of condensation occurring the unit is equipped with 10mm Polyethylene panel insulation for coil & fan section.
SAFETY
Electric panel consists of breakers and contactors for compressors and fan motors, phase sequence relay and other necessary protection devices for the main components. All electric parts are Schneider Electric brand.
*SIEMENS PLC controller is optional.*Main power supply breaker is optional.
EASY INSTALLATION AND MAINTENANCE
The base beams are fixed and provide a rigid foundation for the entire unit. The beam has forklift slots or rigging holes for easy handling. To keep installation as hassle-free as possible, Sendo units are fully factory assembled, tested and charged with R410A refrigerant. Only ductwork and external wiring connections are required to make the units completely operable ensuring rapid, low-cost installation. For ease of commissioning and maintenance, Sendo units include easy access to the electrical cabinet and major refrigeration components. The unit provides external pressure gauge for convenient and fast checking system pressure without removing the panel. If the unit is in running with abnormal operation, the controller will show the error code for easy troubleshooting.
OPTIONAL ACCESSORIES
Tropical climate T3 application
Optional supply / return air configuration
Optional golden condenser & evaporator for some area need special anti-corrosion
Economizer/Free cooling
Additional water heating coil
Additional electric heater
Heat recovery
100% Full fresh air
Optional high level filter
Optional precision temperature & humidity control
Specification
Model | SRT-CT1H80A1E | SRT-CT1H90A1E | SRT-CT1H105A1E | ||
Cooling Capacity | kW | 81 | 90 | 105 | |
Cooling Power Input | kW | 27.3 | 31.9 | 35.6 | |
Heating Capacity | kW | 85.5 | 96.2 | 112 | |
Heating Power Input | kW | 25.6 | 29.4 | 32.9 | |
Compressor | Type | / | Scroll | Scroll | Scroll |
Quantity | Nos | 2 | 2 | 3 | |
Energy Adjustment | % | 33%,67%,100% | 33%,67%,100% | 33%,67%,100% | |
Refrigerant | Type | / | R410A | R410A | R410A |
Condenser Fan | Quantity | Nos | 2 | 2 | 2 |
Type | / | Axial / Direct | Axial / Direct | Axial / Direct | |
Motor Power | kW | 1.1 | 1.1 | 1.1 | |
AirFlow | m3 /h | 33000 | 33000 | 33000 | |
Evaporator Fan | Quantity | Nos | 2 | 2 | 2 |
SupplyAir | m3 /h | 14600 | 16000 | 19000 | |
Type | / | EC Plug-fans | EC Plug-fans | EC Plug-fans | |
ESP | Pa | 100~380 | 100~350 | 100~350 | |
Filter | Type | / | Panel | Panel | Panel |
Level | / | G4 | G4 | G4 | |
Sound Pressure Level | dB(A) | 74 | 74 | 74 | |
Dimension | L | mm | 2500 | 2500 | 2500 |
W | mm | 2200 | 2200 | 2200 | |
H | mm | 1865 | 1865 | 1865 | |
Net Weight | Kg | 1130 | 1160 | 1250 |
Cooling: room air temperature 27.0°C DB RH 50%, ambient air temperature 35°C;
Heating: room air temperature 21.0°C DB, ambient air temperature 7°C DB / 6°C WB.
Noise level measured by adopting average value in the noise lab with background noise of 25 dB(A), at a distance of 1.5m high fan speed.
Specifications are subject to change without prior notice for SENDO product improvement.
Dimension (Model 80~105)
Workshop
Improved energy efficiency through new technology
Sendo contribution to combat rising energy costs and global warming is to design innovative, efficient and dependable HVAC products, while providing best comfort and air quality.
Get in touch with us and book a Factory Tour! Sincerely welcome to visit our factory at your convenience.
Product Categories : Rooftop Packaged Unit > Rooftop Unit With EC Plug Fans
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.